The 'false tacit understanding' between the worker and the owner may hurt both parties

thumbnail

Answering a question from an owner today. The problems encountered by the owner are quite common, but it is quite rare to have two mistakes in one family. In the owner’s own words, everything has come to his house.

The owner’s home has been finished hard-decorated, and now he installs appliances and furniture, and is ready to move into the new house.

There was a problem when installing the gas water heater and range hood. I found that the holes on the flue and the holes drilled before the gas water heater were not correct. Now they can’t be installed. I asked someone to remove the integrated ceiling and re-drilled two holes. After the machine was installed, the ceiling was restored, and more than 1,000 yuan was put in again.

The owner asked me whether the two problems in his house were the worker’s problem or his problem?

This question is really difficult to answer, both wrong and wrong.

Not to mention the problem of the hole puncher, the owner installed the range hood and gas water heater at the wrong time. If they were installed in the normal order, there would not be such a big loss.

According to the normal order, the range hood and gas water heater need to be installed in place before installing the ceiling. Even if the range hood is not installed, the smoke pipe and check valve need to be pre-buried in advance.

If you do these two tasks in advance, you can know whether the original hole is right or wrong before you do the ceiling. Even if you need to re-drill the hole, you can do it with a maximum of 200 yuan. It will definitely not be like So troublesome now.

The wrong construction sequence is also one of the reasons for the loss.

Let’s go back and talk about the hole puncher. The holes of the range hood are made by the hole puncher, and the holes on the flue should be made by the bricklayer.

Many masters will pretend to have a tacit understanding with the owner when they are working. If you don’t ask for it, then I will punch holes according to the normal size. For example, the exhaust pipe of gas water heaters is usually 60, and the exhaust hole is generally 63 or It is 65. The owner used a machine with a 70 exhaust pipe. The original hole will definitely not work.

The size of most of the smoke exhaust holes of the same range hood is also fixed, but there are also individual brands that have requirements on the size. For example, the smoke exhaust holes should be made into a square or a circle, and the diameter should not be smaller.

Deal with these unconventional problems in accordance with the routine. If you don’t talk about it, I won’t talk about it. Then in the end, the problem will not be clear, and both are wrong and not wrong.